Why A Warm Room Can Still Have A Cold Slab
Dew point is the temperature at which air reaches saturation. When moist air meets a slab at or below that temperature, condensation can form on the surface.
Check the coating’s technical data sheet for the required difference between the slab temperature and the dew point. Some products require a margin of at least 3 °C. Use the margin and all other environmental limits for the exact product being applied.
Where To Take The Readings
- Air temperature and relative humidity. Measure the air near the work area to determine its dew point. Check each zone if conditions differ.
- Slab surface temperature. Measure the concrete itself. Include colder spots near loading doors, exterior walls and other exposed edges.
- Dew-point margin. Subtract dew point from slab temperature, using the same units. Record the readings and recheck as conditions change and during the stages specified by the manufacturer.
Worked Example: Two Spots In One Warehouse
The crew measures 20 °C air temperature and 60% relative humidity in both work areas, giving a dew point of about 12 °C. The proposed coating requires the slab to be at least 3 °C above dew point.
- Interior aisle. The slab is 17 °C, about 5 °C above dew point. This meets the example dew-point margin.
- Overhead door. The slab is 13 °C, about 1 °C above dew point. This falls short of the example margin, even if the concrete looks dry.
Hold application near the door until conditions meet the product requirements. Recheck both zones before coating and confirm the remaining limits, including the substrate moisture requirements.
Surface Condensation And Moisture In The Slab
Condensation comes from the surrounding air and forms on the concrete surface. Moisture already in the slab or moving through it is checked separately using the test specified for the flooring system. See Concrete Moisture Before Epoxy and How To Read A Flooring Technical Data Sheet.
Technical References
- National Weather Service Explanation Of Dew Point
- Example Manufacturer Dew-Point Requirement