Epoxology CanadaRequest an Assessment
Back to Learning Centre

Coating Fundamentals

How To Read A Flooring Technical Data Sheet

Find the conditions, coverage and cure information that matter when comparing resinous floor coatings.

Unbranded sample data sheet with five labelled rows for intended use, site conditions, coverage and thickness, pot life and recoat, and return to service.
Illustration. Sample headings for learning. Use the current manufacturer’s sheet for actual values.

Start With The Exact Product And Layer

Get the current technical data sheet for each named product in the proposal. Ask which product is the primer, body coat or topcoat and how the manufacturer specifies the complete system.

The unbranded sample shows where to look. Its headings and notes are illustrative. Use the manufacturer’s current documents for actual limits and instructions.

Five Fields To Check

  • Intended use. Look for the expected traffic, indoor or outdoor exposure, and any documented UV or chemical resistance for the proposed finish.
  • Site conditions. Check substrate preparation, the specified moisture test and limit, and the application limits for slab temperature, air temperature, humidity and dew point.
  • Coverage and film thickness. Check the units and whether the figure is for one coat or the finished system. A wet-film thickness describes the material as applied. Ask how the installer will account for surface profile and porosity.
  • Pot life and recoat window. Pot life is the usable time after mixing under the stated conditions. The recoat window is the interval for applying the next coat. Look for instructions if the window is missed.
  • Return to service. Read the traffic and cure times at the applicable temperature. Ask for written release times for your actual vehicle loads and first cleaning.

Worked Example: A Loading Bay Reopening Monday

The last coat is planned for Saturday afternoon. One proposal highlights early foot access. The other lists a longer cure schedule and depends on a minimum slab temperature. The bay needs loaded forklifts at 6 a.m. Monday, and the slab by the overhead door is cooler than the rest of the building.

For both proposals, ask the installer to measure the slab at the door, confirm the recoat schedule and give a written release time for loaded forklifts based on the products and conditions. Use the time the final coat is completed as the starting point for the release calculation where the manufacturer specifies cure from application. If neither proposal can support the Monday handover, agree on another route or a phased reopening before work starts.

What To Ask The Installer To Confirm

Ask for the full layer schedule, the conditions used to plan the work and the release time for each activity. See Cure Times And Return To Service and Why Epoxy Floors Change Colour In Sunlight.

Technical Reference

  • Example Manufacturer Data For Coverage, Conditions And Cure

Related Lessons

Request an Assessment
Call +1 (905) 840-8405
↑